Canadian owned and operated · Shipping across North America · Low-GWP R-32

Compact-Aire Pro
Pro · 1K · 2K

A reliable, energy-efficient and architecturally discreet through-wall heat pump for multi-residential, hospitality and retrofit projects, including hot water or electric baseboard replacement. Choose the 115/120V plug-in Pro, or the 208/230V Pro 1K and Pro 2K, where the heat pump and its electric back-up heater work together for year-round comfort in cold climates with no exterior equipment and no refrigerant line sets.

10,000BTU/h rated cooling
−15°Cheat pump heating range, all models (5°F)
1 or 2 kWelectric heat, alongside the compressor
32dBA indoor sound
ETL Listed mark (Intertek) R32 refrigerant AHRI Certified, AHRI Standard 210/240 AHRI certified: Pro, Pro 1K and Pro 2K
Compact-Aire Pro through-wall heat pump wall-mounted below a window in a bedroom
COMPACT-AIRE PRO SERIESCold-climate comfort that fits the room, not the other way round.Heating and cooling in one slim unit. No condenser, no line sets, nothing on the balcony.
CHOOSE YOUR MODEL

One cabinet. Three models.

115/120V · PLUG-IN

Compact-Aire Pro (115/120V)

The plug-in model of the Pro series: 10,000 BTU/h of cooling from a standard 115/120V grounded outlet, for rooms where a 208/230V circuit isn't available. No electric back-up heater; heat pump heating rated down to 5°F (−15°C). Model CAPRO0010K115V.

Cooling
10,000 BTU/h · 1,080 W
Heating
9,000 BTU/h · 930 W
Heat pump at 5°F
5,000 BTU/h · COP 1.73
Power supply
115/120V-1-60
MCA / MOP · breaker
14 A / 22 A · 15 A
Safety listing
ETL
Pro series submittal (PDF) →
208/230V · 1 KW HEAT

Compact-Aire Pro 1K

For rooms and suites in mild to cold climates. A 1 kW electric heater supports the compressor in colder weather, with heat pump heating rated down to 5°F (−15°C).

Cooling
10,000 BTU/h
Heating at 47°F
9,000 BTU/h · COP 3.2
Heat pump at 5°F
5,500 BTU/h · COP 1.57
MCA / MOP · breaker
14 A / 19 A · 15 A
Safety listing
ETL
Pro series submittal (PDF) →
208/230V · 2 KW HEATCOLD CLIMATE

Compact-Aire Pro 2K

For colder climates. A 2 kW electric heater runs alongside the heat pump, which is rated down to 5°F (−15°C): 11,824 BTU/h combined output at that temperature.

Cooling
10,000 BTU/h
Heating at 47°F
9,000 BTU/h · COP 3.2
Heat pump at 5°F
5,000 BTU/h · COP 1.73
MCA / MOP · breaker
22 A / 27 A · 20 A plug-in, 25 A hard-wired
Safety listing
ETL
Pro series submittal (PDF) →
VIDEO · 1:55

Meet Compact-Aire Pro.

The mascot speaks as the Compact-Aire Pro: how it works, how cold it goes and what it saves.

COLD-CLIMATE PERFORMANCE

Heat that holds up when it's cold outside.

A heat pump's output drops as the outdoor temperature falls. On the Pro series the electric heater runs alongside the compressor to make up the difference. At 5°F (−15°C) the Pro 2K still delivers 11,824 BTU/h, more than its 9,000 BTU/h rated heat pump output at 47°F.

COMPACT-AIRE PRO Pro 1K

47°F8°C12,412 BTU/hheat pump 9,000 (COP 3.2) + heater 3,412
17°F−8°C9,912 BTU/hheat pump 6,500 (COP 2.25) + heater 3,412
5°F−15°C8,912 BTU/hheat pump 5,500 (COP 1.57) + heater 3,412

COMPACT-AIRE PRO Pro 2K

47°F8°C15,824 BTU/hheat pump 9,000 (COP 3.2) + heater 6,824
17°F−8°C13,324 BTU/hheat pump 6,500 (COP 2.24) + heater 6,824
5°F−15°C11,824 BTU/hheat pump 5,000 (COP 1.73) + heater 6,824

Heat pump output and COP at each outdoor temperature from the 2026 WAYSOS documents (Pro series submittal). Heater output is the rated heater power: 1 kW = 3,412 BTU/h, 2 kW = 6,824 BTU/h. Combined values are the sum of the published heat pump and heater outputs. The heater is switched on from the remote or app and runs only under the conditions described below.

ENERGY EFFICIENCY

More heat out than electricity in.

At rated conditions the Pro 1K and Pro 2K deliver about 2.9 times more cooling and 3.1 times more heat than the electricity they draw, and the 115/120V Pro about 2.7 and 2.8 times. On all three models the inverter compressor runs from 30 to 80 Hz, slowing down as the room approaches its setpoint.

COMPACT-AIRE PRO Pro (115/120V)

Cooling95°F / 35°C outdoor
Electricity in1.08 kW
Cooling delivered2.93 kW
2.7×kW out per kW in
Heating47°F / 8°C outdoor
Electricity in0.93 kW
Heat delivered2.64 kW
2.8×kW out per kW in

COMPACT-AIRE PRO Pro 1K & Pro 2K

Cooling95°F / 35°C outdoor
Electricity in1.02 kW
Cooling delivered2.93 kW
2.9×kW out per kW in
Heating47°F / 8°C outdoor
Electricity in0.85 kW
Heat delivered2.64 kW
3.1×kW out per kW in

Rated capacity and power input from the 2026 WAYSOS documents (Pro series submittal), heat pump only (electric heater off). kW out per kW in is capacity divided by power input at the conditions shown. The published heating COP at 47°F is 2.83 (Pro), 3.2 (Pro 1K) and 3.2 (Pro 2K). Running cost depends on climate, setpoint and electricity rate.

CONTROLS & ELECTRIC HEAT

Every mode, from the wall, the remote or your phone.

Temperature is adjusted with the up and down controls on the unit, the remote or the Smart Life app, within each mode's range. The display switches between °F and °C by pressing both buttons together.

Electric back-up heat

The PTC heater is off by default and is switched on from the remote or app. It then runs together with the compressor, only while all of these are met, and switches back off whenever the unit is turned off or changed to another mode.

Runs when

  • The unit is in heating mode and the compressor has run for 3 minutes
  • Outdoor temperature is below 77°F (25°C)
  • The setpoint is at least 9°F (5°C) above room temperature
  • Room temperature is 64°F (18°C) or lower

Stops when

  • The unit leaves heating mode, defrosts, or the compressor stops
  • Outdoor temperature rises above 82°F (28°C)
  • The room reaches the setpoint, or 73°F (23°C)
  • The fan stops or a sensor fault is detected
Cooling and heating

Setpoint adjustable from 60°F to 86°F (16°C to 30°C), with Low, Medium and High fan speeds. In heating mode the electric heater can be switched on from the remote or app.

Silent mode

Lowers fan speed and compressor frequency for quieter operation. Available in cooling and heating, from the app or remote.

Dehumidification and fan

Dry mode uses a fixed temperature and locked fan speed for effective moisture removal, with condensate drained through the external pipe. Fan mode recirculates room air without heating or cooling.

Swing louvre

The motorized louvre can be switched on from the remote or app to spread airflow evenly through the room.

Timers and display

A 24-hour timer sets a shutdown while running or a delayed start from standby, in 1-hour steps from 1 to 24 hours. The display backlight can be turned off from the remote or app for sleeping.

Wi-Fi and the Smart Life app

Control the unit from your phone: switch it on or off, change mode and setpoint, set the fan speed, swing louvre, silent mode and the 24-hour timer, and on the Pro 1K and 2K switch the electric heater on.

Before you start

  • Your router must provide a 2.4 GHz network. On a dual-band router, give the 2.4 GHz and 5 GHz networks different names
  • Keep the unit close to the router during setup
  • Connect your phone to the router's Wi-Fi and turn off mobile data

Connect

  1. Download Smart Life from the App Store or Google Play and sign up with your email or phone number
  2. Put the unit in standby, then hold the Fan button for 3 seconds until you hear a tone and the Wi-Fi light flashes
  3. Turn on Bluetooth on your phone and open the app. The unit appears automatically: tap Add
  4. Enter your Wi-Fi password and tap Next, then wait for the progress bar to finish

Steps are from the Compact-Aire Pro (115/120V) user manual. App screens may change as the app is updated.

SPECIFICATIONS

Pro, Pro 1K and Pro 2K compared

Through-wall heat pump specifications
MODEL COMPACT-AIRE PROPro (115/120V) COMPACT-AIRE PROPro 1K COMPACT-AIRE PROPro 2K
COOLING
Rated capacity (95°F)10,000 BTU/h10,000 BTU/h10,000 BTU/h
EER29.59.99.9
SEER215.016.416.4
Power input1,080 W1,020 W1,020 W
Outdoor operating range32°F to 113°F32°F to 113°F32°F to 113°F
HEATING — HEAT PUMP ONLY
At 47°F / 8°C9,000 BTU/h · COP 2.839,000 BTU/h · COP 3.29,000 BTU/h · COP 3.2
At 17°F / −8°C6,500 BTU/h · COP 2.246,500 BTU/h · COP 2.256,500 BTU/h · COP 2.24
At 5°F / −15°C5,000 BTU/h · COP 1.735,500 BTU/h · COP 1.575,000 BTU/h · COP 1.73
HSPF27.57.57.5
Power input (47°F)930 W850 W850 W
Outdoor operating range5°F to 75°F5°F to 75°F5°F to 75°F
Electric back-up heatNot fitted1 kW2 kW
Electric heat runs—Alongside the compressorAlongside the compressor
ELECTRICAL & OPERATION
Power supply (V-Ph-Hz)115/120-1-60208/230-1-60208/230-1-60
MCA / MOP14 A / 22 A14 A / 19 A22 A / 27 A
Total input current9.8 A8.7 A14.5 A
Recommended breaker15 A15 A20 A (plug-in) / 25 A (hard-wired)
Indoor airflow200–320 CFM200–320 CFM200–320 CFM
Indoor sound32 dBA32 dBA32 dBA
Safety listingETLETLETL
CERTIFICATION & REBATE DATA
Model numberCAPRO0010K115V——
AHRI certifiedYes · AHRI 210/240Yes · AHRI 210/240Yes · AHRI 210/240
AHRI classificationUnitary Small HP——
AHRI reference numberOn requestOn requestOn request
Safety listing no.Intertek 3118114——
Heating at 5°F / −15°C (COP)COP 1.73COP 1.57COP 1.73
INSTALLATION
Unit size (W × H × D)39.4″ × 23.1″ × 8.07″39.4″ × 23.1″ × 8.07″39.4″ × 23.1″ × 8.07″
Wall openings (supply & exhaust)2 × 8″ dia.2 × 8″ dia.2 × 8″ dia.
Condensate drain1″ dia.1″ dia.1″ dia.
Weight93.5 lb93.5 lb93.5 lb
DocumentsSubmittal (PDF)Submittal (PDF)Submittal (PDF)

Heating values are for the heat pump alone at the outdoor temperatures shown. Values from current WAYSOS documents (2026). Specifications may change without notice. Confirm against the current submittal before design. Compare with the Compact-Aire 3K, 1.4K and HP →

Two cored openings through an exterior wall, with a smaller condensate hole
Two 8″ wall cores and a 1″ condensate hole
Sidewall Adaptor Kit for the Compact-Aire Pro series
Interior wall? The Sidewall Adaptor Kit
INSTALLATION

Installed from inside the room.

  1. Mark the wall with the manufacturer's template and a spirit level, on a sound, flat exterior wall with room around the unit for airflow.
  2. Core two 8″ openings sloped 3–5° down to the outside, and fit the supplied duct sleeves, seam side up, trimmed flush inside.
  3. Route the 1″ condensate drain to a sanitary tie-in, floor drain, riser or the exterior wall, at a slope of at least 5°.
  4. Fit the vent covers from inside the room using the folding method and chain, or optional wall caps from outside where there's access.
  5. Hang the unit on the wall bracket, align the ducts and route the drain, then connect power to national wiring standards.

No exterior wall available? The Sidewall Adaptor Kit mounts the Pro on an interior wall and redirects airflow sideways.

BUILT FOR ANY WEATHER

Rain or snow outside. The same comfort inside.

Everything that heats and cools sits indoors, sealed in the unit. Outside there are only two hooded wall caps facing down, so rain and snow run off instead of in.

Outside on a balcony: two black downward-facing hooded wall caps and a condensate drain on the window infill panel
OUTSIDETwo hooded caps. Nothing else.Downward-facing hoods shed rain and snow. No condenser, no line set, nothing on the balcony floor.
Compact-Aire Pro wall-mounted below a bedroom window
INSIDEAll the equipment stays dry and warm.Compressor, coils, heater and controls sit inside the room, away from the weather.
  • Water stays outHooded caps and duct sleeves sloped 3–5° down to the outside.
  • Heated drain panPrevents ice forming in heating mode, with an overflow safety switch.
  • Heats in the coldHeat pump heating rated down to 5°F (−15°C) on every model, with 1 or 2 kW of electric back-up heat on the Pro 1K and 2K.
FREQUENTLY ASKED QUESTIONS

Pro series questions, answered.

From installers, engineers and building owners. Not covered here? Ask support@waysos.com.

GENERAL

Where is the unit made, and how long has it been in production?

The Compact-Aire Pro is made in China. Production started in 2018, and about 95,000 units are installed across Europe and Canada.

What voltages is it available in?

115/120V for the plug-in Pro, and 208/230V for the Pro 1K and Pro 2K. Circuit sizes for each model (MCA, MOP and breaker) are in the specifications.

What controls come with it?

As standard: the on-board controls, a hand remote and Wi-Fi through the Smart Life app. A third-party 24V wall thermostat can be connected as an option.

How many units can one phone control?

Up to 30 units from the same device in the Smart Life app.

How often does it need maintenance?

Clean the filter about once a month, more often in dusty rooms. It is held by magnets: take it out, vacuum it or wipe it with a damp cloth, and put it back. Don't open the case to clean inside; call a licensed HVAC technician for that.

How much heat is lost through the unit when it is on the wall?

All the cabinet panels are insulated, and a sealing strip between the unit and the wall cuts air leakage around it.

What comes in the box?
  • Wall template and wall hanging bracket
  • 2 exterior round grilles with tension chains
  • 2 interior round duct collars and 2 duct sheets
  • Mounting screws
  • Remote control

Options: the Sunvent connector, made to size and colour for existing openings, and Primex rain hood wall vents in a range of colours.

What makes it different?
  • 32 dBA indoors, with a silent mode
  • No outdoor unit, and no condensate drain needed in cooling mode
  • Both coils have an anti-corrosion blue-fin coating, which helps in coastal air
  • DC inverter compressor and fan, R-32 refrigerant (GWP 675)
  • Wi-Fi control through the Smart Life app

ELECTRIC BACK-UP HEAT

Which models have electric back-up heat?

The plug-in Pro has none. The Pro 1K has a 1 kW heater and the Pro 2K a 2 kW heater. On the Pro 1K the heater gives a constant 1,000 W whether the supply is 208V or 230V.

How is the heater switched on?

Manually, from the on-board controls, the remote or the app, in heating mode. It is off by default and switches off again when the unit is turned off or put in another mode.

Does the heat pump keep running while the heater is on?

Yes. The heater assists the heat pump and runs at the same time, and the fan keeps running. As standard the heater cannot run on its own; electric-only operation is available on bespoke orders.

When will the heater run?

Only when all of these hold, checked over 20 seconds of continuous monitoring:

  • The unit is in heating mode and the compressor has run for 3 minutes
  • Outdoor temperature stays below 77°F (25°C)
  • The setpoint is at least 9°F (5°C) above room temperature
  • Room temperature is 64°F (18°C) or lower
  • Indoor coil temperature is 118°F (48°C) or lower
When does the heater stop?

When the unit's self-test detects any of these:

  • Outdoor temperature above 82°F (28°C) for 10 seconds
  • The room reaches the setpoint, or 73°F (23°C)
  • The compressor stops, or the unit leaves heating mode
  • The fan stops or has a fault
  • The 4-way valve is disconnected
  • Indoor coil temperature reaches 129°F (54°C)
  • The unit is defrosting

DEFROST

How does defrost work?

Defrost is triggered by the outdoor coil temperature. In cold weather the unit defrosts about once every hour of heating, and returns to heating once the outdoor coil has warmed up.

Does the unit keep heating during defrost?

No. Heating pauses for the defrost cycle, then resumes automatically.

CONDENSATE

Is the drain pan heated?

Yes, as standard. The heated pan stops ice forming in heating mode.

What stops the pan overflowing?

A float switch. If the drain is ever blocked, it switches the unit off before water can escape, and the display shows FL.

How much water does it remove in dehumidify mode?

Up to 2.5 pints per hour (1.2 L/h).

Where is the condensate connection?

Underneath the unit, with a right-angle fitting that turns the drain pipe to the back, toward the exterior wall.

Which fans run in dehumidify mode?

Both the indoor and outdoor fans, at low speed.

WARRANTY

Covered in Canada and the United States.

1 YEAR

All parts and labour

Every factory-installed component, including labour to repair or replace defective parts.

3 YEARS

Compressor

Replacement of the original compressor, parts only after the first year.

5 YEARS · OPTIONAL

Extended compressor

Compressor parts, from the date of original installation. Available at additional cost.

Coverage starts on the date of original installation. The unit must be installed and commissioned to WAYSOS instructions and local codes, and serviced by licensed HVAC professionals. Full terms are in the spec sheet. Claims: support@waysos.com.

REBATES & ELIGIBILITY

Applying for a rebate? Here's what programs ask for.

Incentive eligibility varies by province or state, utility and program, and most programs only accept equipment on their own qualifying list. Check eligibility with the rebate provider before you buy. We'll supply the model data and certificates your application needs.

  • Model number and equipment type, shown in the specifications table above.
  • AHRI certificate and reference number for AHRI-certified models (Standard 210/240).
  • Rated efficiency: SEER2, HSPF2 and EER2, plus heating capacity and COP at 5°F for cold-climate programs.
  • Safety listing: ETL (Intertek), the same on every model.
  • Installation by a licensed contractor, with the invoice showing model and serial numbers.
DOCUMENTS

Specifying the Pro series? Download the data, or ask us for drawings and submittals.

Technical support: support@waysos.com · +1 604-401-0298

Heating a cold-climate project? Send us the rooms and we'll size it.

Technical and warranty support: support@waysos.com · +1 604-401-0298