GENERAL
Where is the unit made, and how long has it been in production?
The Compact-Aire Pro is made in China. Production started in 2018, and about 95,000 units are installed across Europe and Canada.
What voltages is it available in?
115/120V for the plug-in Pro, and 208/230V for the Pro 1K and Pro 2K. Circuit sizes for each model (MCA, MOP and breaker) are in the specifications.
What controls come with it?
As standard: the on-board controls, a hand remote and Wi-Fi through the Smart Life app. A third-party 24V wall thermostat can be connected as an option.
How many units can one phone control?
Up to 30 units from the same device in the Smart Life app.
How often does it need maintenance?
Clean the filter about once a month, more often in dusty rooms. It is held by magnets: take it out, vacuum it or wipe it with a damp cloth, and put it back. Don't open the case to clean inside; call a licensed HVAC technician for that.
How much heat is lost through the unit when it is on the wall?
All the cabinet panels are insulated, and a sealing strip between the unit and the wall cuts air leakage around it.
What comes in the box?
- Wall template and wall hanging bracket
- 2 exterior round grilles with tension chains
- 2 interior round duct collars and 2 duct sheets
- Mounting screws
- Remote control
Options: the Sunvent connector, made to size and colour for existing openings, and Primex rain hood wall vents in a range of colours.
What makes it different?
- 32 dBA indoors, with a silent mode
- No outdoor unit, and no condensate drain needed in cooling mode
- Both coils have an anti-corrosion blue-fin coating, which helps in coastal air
- DC inverter compressor and fan, R-32 refrigerant (GWP 675)
- Wi-Fi control through the Smart Life app
ELECTRIC BACK-UP HEAT
Which models have electric back-up heat?
The plug-in Pro has none. The Pro 1K has a 1 kW heater and the Pro 2K a 2 kW heater. On the Pro 1K the heater gives a constant 1,000 W whether the supply is 208V or 230V.
How is the heater switched on?
Manually, from the on-board controls, the remote or the app, in heating mode. It is off by default and switches off again when the unit is turned off or put in another mode.
Does the heat pump keep running while the heater is on?
Yes. The heater assists the heat pump and runs at the same time, and the fan keeps running. As standard the heater cannot run on its own; electric-only operation is available on bespoke orders.
When will the heater run?
Only when all of these hold, checked over 20 seconds of continuous monitoring:
- The unit is in heating mode and the compressor has run for 3 minutes
- Outdoor temperature stays below 77°F (25°C)
- The setpoint is at least 9°F (5°C) above room temperature
- Room temperature is 64°F (18°C) or lower
- Indoor coil temperature is 118°F (48°C) or lower
When does the heater stop?
When the unit's self-test detects any of these:
- Outdoor temperature above 82°F (28°C) for 10 seconds
- The room reaches the setpoint, or 73°F (23°C)
- The compressor stops, or the unit leaves heating mode
- The fan stops or has a fault
- The 4-way valve is disconnected
- Indoor coil temperature reaches 129°F (54°C)
- The unit is defrosting
DEFROST
How does defrost work?
Defrost is triggered by the outdoor coil temperature. In cold weather the unit defrosts about once every hour of heating, and returns to heating once the outdoor coil has warmed up.
Does the unit keep heating during defrost?
No. Heating pauses for the defrost cycle, then resumes automatically.
CONDENSATE
Is the drain pan heated?
Yes, as standard. The heated pan stops ice forming in heating mode.
What stops the pan overflowing?
A float switch. If the drain is ever blocked, it switches the unit off before water can escape, and the display shows FL.
How much water does it remove in dehumidify mode?
Up to 2.5 pints per hour (1.2 L/h).
Where is the condensate connection?
Underneath the unit, with a right-angle fitting that turns the drain pipe to the back, toward the exterior wall.
Which fans run in dehumidify mode?
Both the indoor and outdoor fans, at low speed.