Canadian owned and operated · Shipping across North America · Low-GWP R-32

Air source through-wall heat pumps

A fully self-contained heat pump in a low-profile indoor enclosure. All refrigeration components are factory sealed inside the unit, so there is no outdoor condenser, no refrigerant line set and no building-wide refrigerant or hydronic piping to design, install or maintain.

COMPARE MODELS

Specifications

Through-wall heat pump specifications
MODEL COMPACT-AIRE3K COMPACT-AIRE1.4K COMPACT-AIRE PROPro (115/120V) COMPACT-AIRE PROPro 1K COMPACT-AIRE PROPro 2K COMPACT-AIREHPCOMING SOON
COOLING
Rated capacity (95°F)11,800 BTU/h11,800 BTU/h10,000 BTU/h10,000 BTU/h10,000 BTU/h7,080 BTU/h
EER210.110.19.59.99.910.5
SEER215.5515.5515.016.416.413.9
Power input1,209 W1,209 W1,080 W1,020 W1,020 W846 W
Outdoor operating range64°F to 109°F64°F to 109°F32°F to 113°F32°F to 113°F32°F to 113°F—
HEATING — HEAT PUMP ONLY
At 47°F / 8°C10,900 BTU/h · COP 3.410,900 BTU/h · COP 3.49,000 BTU/h · COP 2.839,000 BTU/h · COP 3.29,000 BTU/h · COP 3.27,120 BTU/h · COP 3.0
At 17°F / −8°C7,180 BTU/h · COP 2.37,180 BTU/h · COP 2.36,500 BTU/h · COP 2.246,500 BTU/h · COP 2.256,500 BTU/h · COP 2.244,405 BTU/h · COP 1.8
At 5°F / −15°C4,370 BTU/h · COP 1.644,370 BTU/h · COP 1.645,000 BTU/h · COP 1.735,500 BTU/h · COP 1.575,000 BTU/h · COP 1.732,825 BTU/h · COP 1.2
HSPF28.28.27.57.57.57.4
Power input (47°F)947 W947 W930 W850 W850 W703.4 W
Outdoor operating range——5°F to 75°F5°F to 75°F5°F to 75°F5°F to 75°F
Electric back-up heat3 kW1.4 kWNot fitted1 kW2 kW600 W
Electric heat runsInstead of the compressorInstead of the compressor—Alongside the compressorAlongside the compressorAlongside the compressor
ELECTRICAL & OPERATION
Power supply (V-Ph-Hz)208/230-1-60208/230-1-60115/120-1-60208/230-1-60208/230-1-60115-1-60
MCA / MOP20 A / 20 A11 A / 15 A14 A / 22 A14 A / 19 A22 A / 27 A13.4 A / 15 A
Total input current——9.8 A8.7 A14.5 A—
Recommended breaker——15 A15 A20 A (plug-in) / 25 A (hard-wired)—
Indoor airflow215–330 CFM215–330 CFM200–320 CFM200–320 CFM200–320 CFM165–235 CFM
Indoor sound32 dBA32 dBA32 dBA32 dBA32 dBA32 dBA
Safety listingETLETLETLETLETLETL
CERTIFICATION & REBATE DATA
Model number——CAPRO0010K115V———
AHRI certifiedIn progressIn progressYes · AHRI 210/240Yes · AHRI 210/240Yes · AHRI 210/240In progress
AHRI classification——Unitary Small HP———
AHRI reference number——On requestOn requestOn request—
Safety listing no.——Intertek 3118114———
Heating at 5°F / −15°C (COP)COP 1.64COP 1.64COP 1.73COP 1.57COP 1.73COP 1.2
INSTALLATION
Unit size (W × H × D)39.4″ × 22.8″ × 8.6″39.4″ × 22.8″ × 8.6″39.4″ × 23.1″ × 8.07″39.4″ × 23.1″ × 8.07″39.4″ × 23.1″ × 8.07″36.81″ × 21.38″ × 7.8″
Wall openings (supply & exhaust)2 × 8″ dia.2 × 8″ dia.2 × 8″ dia.2 × 8″ dia.2 × 8″ dia.2 × 8″ dia.
Condensate drain——1″ dia.1″ dia.1″ dia.1.2″ dia.
Weight117 lb117 lb93.5 lb93.5 lb93.5 lb86 lb
DocumentsSpec sheet (PDF)Spec sheet (PDF)Submittal (PDF)Submittal (PDF)Submittal (PDF)Spec sheet (PDF)
CERTIFIED ETL Listed mark (Intertek) AHRI Certified, AHRI Standard 210/240 All models ETL listed. AHRI certified: Compact-Aire Pro, Pro 1K and Pro 2K, with ratings listed in the AHRI Directory.

Heating values are for the heat pump alone at the outdoor temperatures shown. Electric heat runs alongside the compressor on the HP and Pro models; on the 3K and 1.4K it takes over from the compressor when switched on. Values from current WAYSOS spec sheets (2026). Specifications may change without notice. Confirm against the current submittal before design.

COMPACT-AIRE ELITE · NEXT GENERATION

The vertical ELITE is being redesigned.

The slim, floor-standing through-wall heat pump that fits between windows and in room corners is getting a new design. Register now and we'll send you the first look, specifications and launch details as soon as they're released. Planning a project? Tell us and we'll keep you in the loop for early allocation.

See the ELITE → Need a vertical unit now? Talk to our team about current availability.
IN THE FIELD

Installed in hotels, apartments, care homes and offices.

See projects →
Walk-around of an installed unit in a hotel suite
Through-wall heat pump installed below a large window in a hotel suite
Hotel suite: unit set below the window line
Heat pump under a window in a mass-timber apartment, plugged into a wall outlet
Mass-timber apartment, plug-in connection
Round wall caps and condensate lines on the cedar siding of the Howe Sound Inn, Squamish
Howe Sound Inn, Squamish: round wall caps and condensate lines
Two black hooded wall caps set into a window spandrel panel on a new building
New build: hooded caps in the window spandrel panel
Heat pump on a raised plinth below a window in a care facility room
Care facility room, on a raised plinth
Close-up of the unit's on-board temperature display and touch controls
On-board display and touch controls
Heat pump installed below the window of a ground-floor office
Office retrofit
INSTALLATION

Two wall openings. A wall bracket. A power connection.

No refrigerant handling on site. Shown here: a window-wall retrofit in an occupied suite, with the openings through an infill panel so nothing is cut into the structure.

  1. Indoor view of a window infill panel with two round duct sleeves and a horizontal wall bracket, before the unit is hung
    1Prepare the openingsTwo duct sleeves through the infill panel and the wall bracket fixed above them.
  2. Outdoor view from the balcony: two vent covers on the window infill panel, with the unit visible inside
    2Finish the outsideTwo vent covers on the panel. No condenser, no line set on the façade.
  3. Finished room: the heat pump hung below the window between two armchairs
    3Hang the unit and connectThe unit hangs on the bracket, ducts aligned, and plugs in or is hard-wired.
  1. Core the wall. Two 8″ cores for supply and exhaust air, sloped 3–5° down to the outside, plus a condensate hole. Fit the supplied duct sleeves.
  2. Hang the unit on its wall mounting bracket. No refrigerant handling on site.
  3. Connect power, plug-in or hard-wired by model. The supplied vent covers install from inside the room; optional wall caps go on from outside.

Interior wall or old PTAC opening? See parts & accessories.

REBATES & ELIGIBILITY

Applying for a rebate? Here's what programs ask for.

Incentive eligibility varies by province or state, utility and program, and most programs only accept equipment on their own qualifying list. Check eligibility with the rebate provider before you buy. We'll supply the model data and certificates your application needs.

  • Model number and equipment type, shown in the specifications table above.
  • AHRI certificate and reference number for AHRI-certified models (Standard 210/240).
  • Rated efficiency: SEER2, HSPF2 and EER2, plus heating capacity and COP at 5°F for cold-climate programs.
  • Safety listing: ETL (Intertek); the listing for each model is in the specifications table.
  • Installation by a licensed contractor, with the invoice showing model and serial numbers.

Not sure which model fits? We'll size it for you.

Technical and warranty support: support@waysos.com